„Dry run of brine pump“
brine tank empty
stopcock of brine system not open
lid of metal filter mesh not screwed down firmly
Error message “Brine sensor defective”
Feed pump for brine stuck
Sensor defective or set incorrectly
Check sensor by means of sensor adjustment in service menu. See description k-tronic.
If the screws do not supply,
it is possible that the spreading material has been frozen or foreign material
could have dropped into the spreading container.
Move the screws backward by means of the toggle switch
or the reversing push-button at the slave housing. Switch off the spreading disc at the control system. Press
the toggle switch or the reversing push-button very briefly to rectify a possible error caused by the formation
of clumps. Manual operation is only provided for emergency situation.
In cases where people or the equipment are endangered, shut down the machine immediately and
contact the customer service.
The conveyor screws do not supply enough spreading material in case inappropriate spreading material is filled in
which does not continue to run. Remove the protective cover above the conveyor screws; afterwards, immediately
mount the protective cover again. Mechanic causes are rare; the drive chains of the conveyor screws or the hydraulic
drive motors may be defective
Do not execute any work with the machine operating!
SWITCH OFF THE MOTOR AND REMOVE THE IGNITION KEY!!!
Brine system does not work. Check by means of the emergency manual override at the flow divider block
whether the error is an electrical or a hydraulic error. If the brine pump is running in manual mode, an
electrical error is the cause. Check entered values at the k-tronic. Is the control valve provided with
electricity? If the hydraulic motor with gear pump does not move, check whether the oil supply at the
gear pump is enough. Very rarely, the gear pump or the hydraulic motor is defective or the nozzle is
blocked.
If the spread quantity or the spreading width does not correspond with the desired nominal value, check the
settings on the k-tronic. See Chapter 5 “First setting of spreader”
We recommend checking the settings before the beginning of the season and having them
corrected, if necessary.
Subject to modifications
Chapter 06_
47
www.kugelmann.com
Summary of Contents for DUPLEX INOX
Page 2: ...2 ...
Page 6: ...Error diagnosis 46 Maintenance schedule for three point spreader 48 6 ...
Page 7: ...Chapter 01_7 www kugelmann com CHAPTER 01 Important notes Subject to modifications ...
Page 16: ...Subject to modifications 16_Important notes ...
Page 20: ...Subject to modifications 20_Labeling and warning notes ...
Page 21: ...Chapter 03_21 www kugelmann com Chapter 03 Technical data equipment ...
Page 26: ...26_Technical data equipment ...
Page 30: ...Subject to modifications 30_Installation and removal of spreader ...
Page 31: ...Chapter 05_31 www kugelmann com CHAPTER 05 Operation of spreader Subject to modifications ...
Page 49: ......