RT120Q Operator’s Manual
Service - 157
Recommended Lubricants/Service Key
Approved Fuel
Tier 4i Engine (U.S., Canada, EU, and Japan)
This engine is designed to run on diesel fuel. Use only high quality fuel meeting ASTM D975 No. 2D,
EN590, or equivalent. At temperatures below 32°F (0°C) winter fuel blends are acceptable. See the engine
operation manual for more information.
Biodiesel blends up to 5% (B5) are approved for use in this unit. The fuel used must meet the
specifications for diesel fuel shown above. In certain markets, higher blends may be used if certain steps
are taken. Extra attention is needed when using biodiesel, especially when operating in cold weather or
storing fuel. Contact your Ditch Witch
®
dealer or the engine manufacturer for more information.
Tier 3 Engine (Rest of World)
This engine is designed to run on diesel fuel. Use only high quality fuel meeting ASTM D975 No. 2D,
EN590, or equivalent. At temperatures below 32°F (0°C) winter fuel blends are acceptable. See the engine
operation manual for more information.
Biodiesel blends up to 5% (B5) are approved for use in this unit. The fuel used must meet the
specifications for diesel fuel shown above. In certain markets, higher blends may be used if certain steps
are taken. Extra attention is needed when using biodiesel, especially when operating in cold weather or
storing fuel. Contact your Ditch Witch dealer or the engine manufacturer for more information.
Avoid static electricity when fueling. Ultra Low Sulfur Diesel (ULSD)
poses a greater static ignition hazard than earlier diesel formulations. Avoid death or
serious injury from fire or explosion. Consult with your fuel system supplier to ensure the
delivery system is in compliance with fueling standards for proper grounding and bonding
practices.
NOTICE:
Use only Ultra Low Sulfur Diesel (less than 15 ppm (15 mg/kg) sulfur content) in this unit.
Operating with higher sulfur content will damage the engine and aftertreatment device.
IMPORTANT:
Worldwide, fuel sulfur regulations vary widely. Fuel used should always comply with local
regulations. Prior to shipping, Tier 3 units were filled with API CJ-4 DEO. If operating fuel with sulfur
content above 500 ppm (500 mg/kg), change oil initially at 100 hours.
Summary of Contents for RT120Q
Page 1: ...RT120Q Operator s Manual Issue 2 0 Original Instruction 053 2634 ...
Page 7: ...Overview 6 RT120Q Operator s Manual About This Manual ...
Page 75: ...Operation Overview 74 RT120Q Operator s Manual Leaving Jobsite ...
Page 83: ...Prepare 82 RT120Q Operator s Manual Check Supplies and Prepare Equipment ...
Page 89: ...Drive 88 RT120Q Operator s Manual Shut Down ...
Page 101: ...Transport 100 RT120Q Operator s Manual Retrieve ...
Page 115: ...Plow 114 RT120Q Operator s Manual Finish Job ...
Page 127: ...Backhoe 126 RT120Q Operator s Manual Finish Job ...
Page 140: ...RT120Q Operator s Manual Saw 139 Saw Chapter Contents Set Up 140 Operate 141 Finish Job 143 ...
Page 145: ...Saw 144 RT120Q Operator s Manual Finish Job ...
Page 193: ...Service 192 RT120Q Operator s Manual As Needed ...
Page 213: ...Specifications 212 RT120Q Operator s Manual Declaration of Conformity Information ...
Page 216: ......
Page 217: ......
Page 218: ...RT120Q Operator s Manual Service Record 217 Service Record Service Performed Date Hours ...
Page 219: ...Service Record 218 RT120Q Operator s Manual Service Performed Date Hours ...