G-12
GL6000, GL7000, GL9000, GL11000, WSM
G
GENERAL
6. MAINTENANCE CHECK LIST
Observe the following for service and maintenance.
The lubricating oil change intervals listed in the table below are for classes CG, CE and CD lubricating oil of API
classification with a low-sulfur fuel in use. If the CF-4 of CG-4 lubricating oil is used with a high-sulfur fuel, change the
lubricating oil at shorter intervals than recommended in the table below depending on the operating condition.
CAUTION
• When checking and servicing the generator, be sure to level and stop the engine.
No.
Period
Item
Daily
Initial
50
hours
Every
50
hours
Every
100
hours
Every
200
hours
Every
300
hours
Every
400
hours
Every
500
hours
Reference
page
1
Engine oil
Check
G-14
Change
G-15, 16
2
Radiator coolant (L.L.C.)
Check
G-14
Change
G-24
3
Air cleaner element
Clean
G-17
Change
G-24
4
Fan belt
Check
G-17
Change
G-23
5
Fuel line
(Fuel hose and clamp bands)
Check
G-16
Change
G-25
6
Battery
Check
G-15, 17
Change
G-25
7
Radiator hose and clamp bands
Check
G-18
Change
G-25
8
Oil filter cartridge
Change
G-15, 18
9
Fuel filter element
Clean
G-18
Change
G-19
10
Valve clearance
Check
G-22
11
Water jacket (Radiator interior)
Clean
G-20
12
Generator's brush ware
Check
G-19
13
Generator's slip-ring
Check
G-19
14
Generator's ball bearing
Check
G-23
15
Damage in electric wiring and
loose connections
Check
2-M8
16
Fuel injection pressure
Check
G-23
17
Nozzle spraying condition
Check
G-23
18
Nozzle valve seat tightness
Check
G-23
KiSC issued 05, 2015 A