2-S19
GL6000, GL7000, GL9000, GL11000, WSM
GENERATOR
Rotor Assembly
1. Remove the cooling fan (2).
2. To avoid damage to the rotor assembly (1), suspend the rotor
assembly (1) with a sling belt enough to keep it from lifting, and
leave it suspended.
3. Remove the rotor assembly mounting screws.
4. Remove the rotor assembly (1), take care not to damage the
winding.
(When reassembling)
• Clean any oil and dirt from the mounting surfaces of the rotor and
flywheel. If this is not done correctly, it will result in damage of
rotor and stator caused by loose fittings.
• Handle carefully to avoid damaging the winding.
W1066726
Replacing Ball Bearing
1. Hook the puller until it clicks onto the outer bearing ring and then
pull off the bearing.
(When reassembling)
• Keep new bearing sealed until use.
• Clean dirt from the bearing housing.
• When tapping in the bearing, press it by tapping on the inner race
gently with special tool
W1067349
Tightening torque
Cooling fan mounting
screw
19.6 to 27.4 N·m
2.0 to 2.8 kgf·m
14.5 to 20.3 lbf·ft
Rotor
assembly
mounting
screw
GL6000,
GL7000
34.3 to 44.1 N·m
3.5 to 4.5 kgf·m
25.3 to 32.5 lbf·ft
GL9000,
GL11000
19.6 to 27.4 N·m
2.0 to 2.8 kgf·m
14.5 to 20.3 lbf·ft
(1) Rotor Assembly
(2) Cooling Fan
(1) Ball Bearing
KiSC issued 05, 2015 A