2-S16
GL6000, GL7000, GL9000, GL11000, WSM
GENERATOR
(2) Emergency Relay Activates
Emergency Relay Circuit
1. When the engine is running at rated rpm's connect the lead wires
to the terminal of the oil switch (1) or the water temperature
switch (2).
2. Also ground the other end of the lead wires to an unpainted
portion of the engine frame.
(In normal operation)
• The stop solenoid activate and the engine stops automatically.
• After 7 to 13 seconds ia "tick" sound can be heard and the stop
solenoid is released.
Oil Switch
1. The oil switch (1) has continuity when the engine is stopped and
has no continuity while the engine is running.
2. Replace the oil switch (1) if it is defective.
W1020329
Water Temperature Switch
1. Insert the water temperature switch (1) in the engine oil, and
continue the circuit when the oil temperature rises to 112 to 118
C (234 to 244
F).
2. Check that the resistance is 0 ohm in case water temperature
switch is defective.
IMPORTANT
• Be careful when handling the water temperature switch so
that you do not drop it.
• When assembling the switch, apply sealing agent to the
threads, and then screw it in firmly.
• Make a test run after installation, to check for any water
leaks.
W1020452
(1) Oil Switch
(2) Water Temperature Switch
Resistance (Switch
terminal -Chassis)
In normal state
Infinity
At pressure over
approx. 98 kPa
(1.0 kgf/cm
2
, 28 psi)
0
(1) Oil Switch
Water temperature
switch
Factory spec.
Water temperature above
than 112 to 118
C (234 to
244
F). Contact ON.
(1) Water Temperature Switch
KiSC issued 05, 2015 A