4.13 Checking magnetic switch
continuity
CAUTION
• To prevent an accidental short circuit, attach
the positive cable to the positive terminal before
the negative cable is attached to the negative
terminal.
• Do not remove the battery cap while the engine
operates.
• Keep electrolyte away from eyes, hands and
clothes.
If you are spattered with it, clean with water
immediately.
• Keep open sparks and flames away from the
battery at all times.
Hydrogen gas mixed with oxygen becomes very
explosive.
Tools required
• Circuit tester
1. Push in the plunger.
2. Check the continuity across the C terminal (1) and
the B terminal (2) with a circuit tester.
NOTE
• If it is not continuous or it shows a value,
replace the magnetic switch.
Resistance be-
tween the C termi-
nal (1) and the B
terminal (2)
Service specifi-
cation
0 Ω
(1) C terminal
(2) B terminal
4.14 Checking alternator on unit
CAUTION
• To prevent an accidental short circuit, attach
the positive cable to the positive terminal before
the negative cable is attached to the negative
terminal.
• Do not remove the battery cap while the engine
operates.
• Keep electrolyte away from eyes, hands and
clothes.
If you are spattered with it, clean with water
immediately.
• Keep open sparks and flames away from the
battery at all times.
Hydrogen gas mixed with oxygen becomes very
explosive.
NOTE
• Before check alternator on unit, do a check of
the below list.
– Battery terminal connections
– Circuit connection
– Fan belt tension
– Charge indicator lamp
– Fuses on the circuit
– Abnormal noise from the alternator
– Prepare full charged battery for the test.
• Do not touch the engine parts that turns while
the engine operates.
• Keep a safety distance from the engine parts
that turn.
Tools required
• Circuit tester
1. Start the engine.
2. Measure the voltage between battery terminals.
NOTE
• If the results of alternator-on unit test are
not
in
the
service
specifications,
disassemble the alternator and check each
component part to find out the problem.
• Refer to the alternator section about
Disassembling, Assembling and Servicing.
Regulating voltage
at no load
Service specifi-
cation
13.8 to 14.8 V
(at 25
℃
(77
℉
))
SERVICING
4. Checking and adjusting
4. ENGINE
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
4-105
KiSC issued 12, 2018 A
Summary of Contents for D1803-CR-E4
Page 17: ...1 SAFETY KiSC issued 12 2018 A ...
Page 24: ...2 GENERAL KiSC issued 12 2018 A ...
Page 67: ...3 MAINTENANCE KiSC issued 12 2018 A ...
Page 100: ...4 ENGINE KiSC issued 12 2018 A ...