5. Check the subsequent valve clearance (5) at the
mark
[1TC]
with a feeler gauge.
NOTE
• If the clearance (5) is out of the service
specifications, adjust with the adjusting
screw (3).
• Tighten the lock nut (4) of the adjusting
screw.
Valve clearance
(5) (cold)
Service specifi-
cation
0.18 to 0.22 mm
0.0071 to 0.0086 in.
Adjustable cylinder loca-
tion of piston
Valve arrangement
3 cylinder
4 cylinder
Intake
Ex-
haust
Intake
Ex-
haust
When No. 1 pis-
ton is at com-
pression top
dead center.
1
☆
☆
☆
☆
2
☆
☆
3
☆
☆
4
-
-
When No. 1 pis-
ton is at overlap
position.
1
2
☆
☆
3
☆
☆
4
-
-
☆
☆
(3) Adjusting screw
(4) Lock nut
(5) Valve clearance
6. Install the removed parts.
Tightening tor-
que
Cylinder head cov-
er screw
6.86 to 11.3 N
⋅
m
0.700 to 1.15 kgf
⋅
m
5.06 to 8.33 lbf
⋅
ft
8. Check points of every 1500
hours
8.1 Checking injector (with
Diagmaster)
Tools required
• Laptop computer (Diagmaster (software) installed)
• Interface (DST-i)
1. Connect the diagnosis tool.
2. Start "Diagmaster", then click the
[Active Test]
button (1) from the project window.
3. Select the "#1, 2, 3 and 4 Cylinder Injector Injection
Stop" item (2), then click the
[proceed]
button (3).
(1) Active Test button
(2) #1, 2, 3 and 4 Cylinder Injec-
tor Injection Stop item
(3) Proceed button
4. Select the "#Cylinder Injector Injection Stop" (7)
from the "select signal group" (8).
5. Select the "number of graph" (6).
6. Click the
[Start Active Test]
button (4), then click
the
[OK]
button (5).
(4) Start Active Test button
(5) OK button
(6) Number of graph
(7) #Cylinder Injector Injection
Stop
(8) Select signal group
CHECK AND MAINTENANCE
8.Check points of every 1500 hours
3. MAINTENANCE
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
3-17
KiSC issued 12, 2018 A
Summary of Contents for D1803-CR-E4
Page 17: ...1 SAFETY KiSC issued 12 2018 A ...
Page 24: ...2 GENERAL KiSC issued 12 2018 A ...
Page 67: ...3 MAINTENANCE KiSC issued 12 2018 A ...
Page 100: ...4 ENGINE KiSC issued 12 2018 A ...