PM warning level
Regeneration method
Regeneration status
Control
Automatic active
regeneration
Parked active re-
generation
Regeneration
with service
tools
2-1
Automatic active
regeneration
○
×
○
When the warning level
reaches 2, regeneration is
started automatically.
4.
If the DOC temperature
is 550
℃
(1022
℉
) or
higher, the PM com-
busts on its own so
post injection is not per-
formed (Passive regen-
eration state).
2-2
Require parked
active regenera-
tion
×
○
○
If PM warning level does not
fall to 0 within 30 minutes af-
ter started automatic active
regeneration, parked active
regeneration is required.
1.
Stop the machine at
safty position.
2.
The
intake
throttle
valve is operated re-
ducing the amount of
intake air raising the
exhaust temperature.
3.
Engine speed is raised
and adjusted so that
the DOC temperature
rises to 250
℃
(482
℉
)
or higher.
4.
After the DOC reaches
250
℃
(482
℉
) or high-
er, control is performed
the same as for auto
regeneration.
5.
When regeneration is
finished, the operation
state is returned what it
was prior to auto regen-
eration (idle speed).
3
Parked active re-
generation
(
with
output limitation
)
×
○
○
Automatic active regenera-
tion stops.
Require parked active re-
generation with machine
stop.
4
Regeneration with
Diagmaster
(
with
output limitation
)
×
×
○
Parked active regeneration
becomes impossible.
Need to use Diagmaster for
regeneration.
Regenerate using diagnostic
tool (Diagmaster).
5
Cleaning DPF
(
with output limi-
tation
)
×
×
×
Regeneration with Diagmas-
ter becomes impossible.
Need to change or clean
DPF.
-
MECHANISM
9. Aftertreatment system
4. ENGINE
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
4-77
KiSC issued 12, 2018 A
Summary of Contents for D1803-CR-E4
Page 17: ...1 SAFETY KiSC issued 12 2018 A ...
Page 24: ...2 GENERAL KiSC issued 12 2018 A ...
Page 67: ...3 MAINTENANCE KiSC issued 12 2018 A ...
Page 100: ...4 ENGINE KiSC issued 12 2018 A ...