e
n
g
lis
h
Options:
x = 5: no backlight
x = 6: with backlight
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A: Counting input
INP B: Counting direction input
Up.Dn:
Differential counting input
INP A: Adding counting input
INP B: Subtracting counting input
Quad:
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Quad2:
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
Table 1
Model
Operating mode
Counting inputs
INP A
INP B
6.130.012.8x0
6.130.012.8x2
6.130.012.8x3
6.131.012.8x0
6.131.012.8x1
6.131.012.8x3
AC/DC
6.132.012.8x3
6.133.012.8x0
6.133.012.8x1
Count
0
0 ... 0,7 V DC
NPN
0
7 kHz
0
0 ... 0,7 V DC
NPN
30 Hz
10 ... 260 V AC/DC AC/DC
30 Hz
Cnt.Dir/Up.Dn
Up.Dn
Cnt.Dir
Quad/Quad2
NPN
PNP
AC/DC
NPN
PNP
0
0 ... 0,7 V DC
0
4 ... 30 V DC
10 ... 260 V AC/DC
10 ... 260 V AC/DC
0
0 ... 0,7 V DC
0
4 ... 30 V DC
0
7 kHz
12 kHz
30 Hz
30 Hz
0
3 kHz
0
6 kHz
0
0 ... 0,7 V DC
10 ... 260 V AC/DC
0
0 ... 0,7 V DC
0
4 ... 30 V DC
10 ... 260 V AC/DC
10 ... 260 V AC/DC
0
0 ... 0,7 V DC
0
4 ... 30 V DC
NPN
AC/DC
NPN
PNP
AC/DC
AC/DC
NPN
PNP
0
7 kHz
12 kHz
30 Hz
30 Hz
0
3 kHz
0
6 kHz
0
4 ... 30 V DC
PNP
12 kHz
Overview
0
–
with the intended temperature, voltage and power
ranges. The standards of the respective countries
apply.
DC versions:
Use shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance or con-
nect not used count inputs to ground (0 V).
AC versions:
Use shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance.
1.9 Operation
Is the device set and programmed correctly (function;
for counters, max. counting frequency)?
1.10 Failure possibilities and causes
Impossible to use the keys:
- Key lock input activated
Counter does not count:
- Wrong or reversed wiring of the counting input
- Setting of an input signal not matching the pulse gen-
erator
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator
and the counter
- Maximum counting frequency exceeded
- Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce a
possibly existing defect and to repair your device as
quickly as possible.
2