KTS-Electronic GmbH & Co. KG
– GOLD SCAN II
9
After each of the following changes please press the
Reset-
button:
1. After every engaging of the metal detector.
2. After each change of searchcoils.
3. During the search, if sound becomes instable due to bad ground conditions or
geomagnetism.
To create the search more target-oriented and therefore more successful
– especially
before excavation
– please draw your attention to the following:
1. Change of sound (frequency)
2. Intensity of sound
3. Continuity of sound
4. Extent of value (digital display)
The change of sound is the first sign for the detection of a metal object. Before
excavation, however, further details should be taken into account and the own search
experience should be used for help:
The more intense the sound, the larger the metal object and the nearer the position
to the surface. While the high search tone is audible, it is required to move the
searchcoil in the close surrounding to determine the shape of the metal object.
ID (metal discrimination):
Compared to the predecessor model, in which only a single measurement was
conducted, GOLD SCAN II enables the discrimination by a special measuring
method. Now 5 measurements are carried out, which will calculate the average
value. The average value calculation leads to a more precise metal type
discrimination. The extent of the metal type range makes it possible to distinguish
different size metal objects with the appropriate values from one another. The
average value is shown in sector gold with 100-1000, in the range of copper with
1000-2500 and in the field of light metals, e.g. aluminum, as of 2500.
Unlike to other metal detectors a constant metal discrimination takes place at the
GOLD SCAN II. Conductivity value and metal type (e.g.
“Gold”) are indicated on the
display.
Note
: The new GOLD SCAN II shows a very sensitive reaction towards small gold objects
(e.g. nuggets). Through the increase of frequency the depth performance also rises. Due
to difficult soil conditions it can occur, that interferences will escalate. With a renewed
Reset
and a reduction of frequency this can be lowered.