background image

Installation Manual

Impaq SC-W

INS876-1

Summary of Contents for Impaq SC-W

Page 1: ...Installation Manual Impaq SC W INS876 1 ...

Page 2: ...uration 5 2 2 Additional inputs 1 2 6 2 3 Learning the device to the system 6 2 4 Using the device with a roller shutter contact 7 3 0 Wireless range test 8 4 0 Mounting 8 4 1 Device mounting 8 4 2 Magnet positioning 9 5 0 Setting the shock sensitivity 12 6 0 Specifications 14 7 0 Legal Information 14 ...

Page 3: ...ors When using Premier Elite Firmware Version 2 10 and above the dedicated Ricochet learn menu can be accessed via the omit key when in the Engineers menu For all other firmware versions please refer to the Premier Elite 8XP W 32XP W Installation Manual See the Premier Elite 8XP W 32XP W Installation Manual for details of how to change the device attributes and learning Figure 1 shows the key parts...

Page 4: ...INS876 1 4 15 ...

Page 5: ...uld be changed after the device is learnt to the system unless you are only using the device as a Ricochet wireless repeater DIP Switch Controls M Magnetic contact sensor S Shock sensor T1 Terminal 1 T2 Terminal 2 Note 1 Terminal 2 functions as a tamper input To enable this configure the DIP switch labelled T2 to the ON position Note 2 To comply with EN50131 2 8 move ONLY DIP switch S to the ON pos...

Page 6: ...e system Select an empty zone slot for the device and put the system into learn mode To power up press and hold the sensitivity button for 3 seconds The LED will flash pink while it communicates to the receiver The LED will turn green if the device has successfully learnt onto the system If the LED turns red the learn has failed Check the system is in learn mode Move closer to the panel or expander...

Page 7: ...orced entry The device is compatible with all microswitch 2 wire roller shutter contacts To learn the device with a roller shutter contact Connect the roller shutter contact to terminal 1 Complete the learn process by following the steps in section 2 3 Configure the DIP switch labelled T1 to the ON position To test the device Once the device is learnt to the system pull the cord on the roller shutt...

Page 8: ...device leaves commission mode the device will not show any status LED s 4 0 Mounting 4 1 Device mounting Select the intended mounting position The device can be installed in any mounting orientation Open the device cover and remove the PCB using a screwdriver see figure 4 To ensure product compliance with EN50131 fix both the detector and the rear tamper insert to the mounting surface using the foll...

Page 9: ...PCB the LED will pulse green indicating a secure state The magnet can be installed on either side of the device However greater sensitivity is achieved by placing the magnet at the bottom right of the device and aligning the notch and the arrow see figure 5 for magnet distances If the device LED pulses red move the magnet closer to the device until the LED turns green ...

Page 10: ...INS876 1 10 15 The LED indication for magnet positioning is time limited whilst the system is in commission mode Figure 5 Side of Device Axis Approach Min mm Removal Max mm ...

Page 11: ...INS876 1 11 15 Right X 33 36 Y 6 7 5 Y 6 8 Z 50 52 Z 35 41 Left X 24 30 Y 5 7 Y 7 8 5 Z 52 56 Z 27 33 Once the correct position has been located fix the magnet in place see figure 6 Figure 6 ...

Page 12: ...INS876 1 12 15 5 0 Setting the shock sensitivity Within 10 minutes of learning the device or by activating walk test mode double press the sensitivity button and the LED will flash blue defaulting to ...

Page 13: ...al Radius 1 Wood 1m 2 Framed Glass Window 1m 5 Concrete 0 5m Before testing the device press and hold the button 3 secs to set the desired sensitivity setting The LED will turn green for confirmation at which point the device is ready for impact testing On impact test if the LED turns red the selected sensitivity setting is appropriate for the installation If it doesn t turn red select the next sen...

Page 14: ...r Category 1 Class 2 Receiver LBT Listen Before Talk Transmitter Duty Cycle 1 Max RF Power 10mW Low Voltage Signal 2 50V Operating Voltage 3V Maximum Current 12mA Quiescent Current 19μA Relative Humidity 0 95 non condensing Operating Temperature 10 C to 55 C Weight 80g Dimensions 130mm x 26mm x 25mm magnet 57mm x 11 5mm 7 0 Legal Information Supplier Texecom Ltd Haslingden Lancashire BB4 4PW UK Ma...

Page 15: ...nnot accept responsibility or liability for any damages whatsoever based on a claim that the Impaq SC W failed to function correctly Due to our policy of continuous improvement Texecom reserves the right to change specification without prior notice Domestic Use If this product is installed within reach of children the screw cover should not be fitted as this could cause a choking hazard Hereby Texec...