04/SHOCK ABSORBER, SWINGARM
59
200269-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
4
to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
200270-10
–
When the pressure gauge reaches the required value, turn control lever
Oil reser-
voir
5
to
Vacuum
.
Guideline
0 bar
The vacuum gauge drops to the required value.
8 mbar
200267-10
–
When the vacuum gauge reaches the required value, turn control lever
Oil reser-
voir
5
to
Equalize Pressure
.
Guideline
8 mbar
The pressure gauge drops to the required value.
0 bar
200268-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
4
to
Pressure
.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge increases to the required value.
3 bar
200269-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
4
to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
–
When the pressure gauge reaches the required value, activate the
On/Off
switch.
Guideline
0 bar
The vacuum pump is switched off.
201626-10
–
Slide O-ring
B
to the end of the special tool by the specified value (distance
A
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
–
Push the floating piston into the reservoir to the distance described above using the
special tool.