01/FORK, TRIPLE CLAMP
22
200702-10
Main work
–
Clamp the compression damping fitting in a bench vise using soft jaws.
–
Remove nut
1
.
–
Remove the spring.
–
Remove washer
2
.
200703-10
–
Remove piston
3
.
–
Remove shim stack
4
.
200704-10
–
Remove O-ring
5
and seal ring
6
from the compression damping fitting.
–
Extract the compression damping fitting.
5.16
Checking the fork legs
Condition
The fork legs must be disassembled.
200728-10
–
Check the inner tube and axle clamp for damage.
» If there is damage:
–
Change the inner tube.
200684-10
–
Measure the outside diameter at several locations on the inner tube.
Outside diameter of the inner tube
47.975… 48.005 mm (1.88878…
1.88996 in)
» If the measured value is below the specified value:
–
Change the inner tube.