8
SHOCK ABSORBER, SWINGARM
48
201285-10
–
Measure distance
A
between the floating piston and reservoir hole with the special
tool.
Depth micrometer (T107S) (
p. 219)
The floating piston is positioned all the way at the bottom.
200267-10
–
When the vacuum pressure gauge reaches the specified value, turn the
Oil reser-
voir
control lever
5
to
Equalize pressure
.
Guideline
4 mbar
The pressure gauge rises to the specified value.
0 bar
200268-10
–
When the pressure gauge reaches the specified value, turn the
Damper
control
lever
4
to
Pressure
.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200269-10
–
When the pressure gauge reaches the specified value, turn the
Damper
4
control
lever to
Vacuum
.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
200270-10
–
When the pressure gauge reaches the specified value, turn the
Oil reservoir
5
con-
trol lever to
Vacuum
.
Guideline
0 bar
The vacuum gauge falls to the specified value.
4 mbar
200267-10
–
When the vacuum pressure gauge reaches the specified value, turn the
Oil reser-
voir
control lever
5
to
Equalize Pressure
.
Guideline
4 mbar
The pressure gauge falls to the specified value.
0 bar