ELECTRICAL SYSTEM/ BATTERY
•
Keep the battery away from ignition sources.
•
6KXWRIIWKHFKDUJHU¿UVWRQFHFKDUJHLVVWDUWHGRU¿QLVKHG
VRDVWRSUHYHQWH[SORVLRQKD]DUGFDXVHGE\ÀDVKHVDWWKH
interconnecting part.
•
Charge operation must follow the marked time on the battery.
•
)DVWFKDUJLQJFDQQRWEHXVHGH[FHSWLQFRQWLQJHQF\VLWXD
-
tions.
•
Do not measure the voltage until 30 minutes after the charge.
SPECIFICATION - BATTERY
ITEM
STANDARD VALUE
Battery
Type
Maintenance free
Capacity
12V / 6Ah
Voltage
13.1 - 12.3 V
Charging current
Standard
0.6 A
Quick
6.0 A
Charging period
Standard
10-15 h
Quick
30 min
TROUBLESHOOTING - BATTERY/ CHARGING SYSTEM
FAILURE
CAUSE
TO DO
No power supply
Defect battery
Find the cause and replace the
battery.
Disconnected battery cable
Connect the battery cable.
Fuse blown
Find the cause, repair it and re-
place the fuse.
Faulty main switch
Replace the main switch.
Low power
Weak battery
Charge the battery or replace it.
Loose battery connectio
Tighten the connection.
Charging system failure
Check the components step by
step and replace the defects parts.
)DXOW\UHJXODWRUUHFWL¿HU
5HSODFHWKHUHJXODWRUUHFWL¿HU
Intermittent power
Loose battery cable connection
Tighten the connection.
Loose charging system connection
Tighten the connection.
Loose connection or short circuit in
ignition system
Tighten the connection and repair
the affected component.
Charging system failure
Loose, broken or shorted wire or
connector
Tighten the connection and repair
the affected component.
)DXOW\UHJXODWRUUHFWL¿HU
5HSODFHWKHUHJXODWRUUHFWL¿HU
Faulty generator
Check and replace the generator if
necessary.