6 Servicing/Maintenance
24 of 34
Deep Lift System
2553.89/04-EN
Permissible deviation to DIN 15429 (section 5.1) ≤ 10 %. Any parts with a greater
deviation must be replaced.
Maintenance work
▪
Lubricate the moving parts.
▪
Check that the moving parts can move freely.
▪
Check the spring tension.
▪
Check for any damage.
6.3 Cleaning
WARNING
Fluids handled, consumables and supplies which are hot and/or pose a health
hazard
Hazard to persons and the environment!
▷
Collect and properly dispose of flushing fluid and any fluid residues.
▷
Wear safety clothing and a protective mask if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
If the fluids the lifting accessories have been used in leave residues which might lead
to corrosion damage when coming into contact with atmospheric humidity, or which
might ignite when coming into contact with oxygen, the lifting accessories must be
flushed, neutralised, and treated with anhydrous inert gas for drying purposes.
6.4 Spare parts stock
6.4.1 Ordering spare parts
Always quote the following data when ordering replacement or spare parts:
▪
Order number
▪
Order item number
▪
Type series
▪
Size
▪
Material variant
▪
Year of construction
Refer to the name plate for all data.
Also specify the following data:
▪
Part number and description
▪
Quantity of spare parts
▪
Shipping address
▪
Mode of dispatch (freight, mail, express freight, air freight)