4 Description
14 of 34
Deep Lift System
2553.89/04-EN
4.7 Operating limits
Observe the following parameters and values during operation:
Parameter
Value
Limits of use
▪
Submersible pumps made by KSB
▪
Permissible load-carrying capacity
(
Space limits
▪
Maximum bail dimensions of the submersible
pump (
▪
Specific design and dimensions for
submersible pumps made by KSB
▪
Maximum dimensions of the pump sump
Time limits
▪
Maximum 20,000 load cycles and/or 20 years
from commissioning of the component
2)
▪
Scheduled checks/inspection of the lifting
accessory, especially the load-carrying
components (hook, spring, etc.)
Applications
▪
Pump installations
▪
Industrial plants
▪
Chemical plants
▪
Waste water treatment plants
Fluids handled
▪
Fluids for which the submersible pumps have
been approved
▪
Fluids which are neither chemically nor
mechanically aggressive to the pump and
component materials
Temperature range
▪
-20 °C to +80 °C
▪
-4 °F to +176 °F
4.8 Tightening torques
Table 6:
Tightening torques
Thread
Quality
[Nm]
[ft lbs]
M8
8.8
35
18
M10
8.8
63
32
4.9 Materials
Table 7:
Overview of materials used
Component
Material
Support frame
Unalloyed quality steel (S355J2) [1.0570]
Load-carrying rod of the Support frame
Stainless austenitic-ferritic chrome nickel molybdenum steel (X2CrNiMo
22-5-3) [1.4462]
Hook
High-strength fine grain structural steel (S550Q) [1.8904]
Pin
Stainless austenitic-ferritic chrome nickel molybdenum steel (X2CrNiMo
22-5-3) [1.4462]
2)
A minimum of 2 load cycles is required each time the pump is lowered or pulled up.