KRONE operation terminal Gamma
80
Pos : 16.24. 33 / BA/ Info-C enter/ Sc hwader/Bedienei nheit - Komf ort/ SW 2000/Haupt menüs/H aupt menü 4 Ser vice/Menü 4-2 Sens ort est H and SW 2000 @ 61\ mod_1298904084182_78. doc @ 568386 @ 3 @ 1
6.14.1 Menu 4-2 "Manual Sensor Test"
SW2000074
4-2
SW2000045
2
B 1
B 2
OFF
ON
Fig. 54
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
CAUTION!
The PTO must not be turning during the sensor test.
Calling the Menu
Main menu 4 "Service" is called.
•
You can select menu 4-2
with the rotary potentiometer. The icon is displayed
inversely
•
Press the rotary potentiometer
The display shows menu 4-2 "Manual sensor test"
Selecting the sensor
•
Select the sensor with the rotary potentiometer
The selected sensor is displayed inversely and is tested.
Pos : 16.24. 34 / BA/ Info-C enter/ Sens or en/Di agnos e N amurs ensor en @ 19\ mod_1238072125300_78. doc @ 214095 @ @ 1
Diagnostics – Namur sensors
Pos : 16.24. 35 / BA/ Info-C enter/ Sc hwader/Bedienei nheit - Komf ort/ Swadro 1400/Haupt menüs/H aupt menü 4 Ser vice/Ei nst ellwert e Sens or allgemei ner T ext @ 6\ mod_1215416779856_78.doc @ 101137 @ @ 1
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos : 16.24. 36 / BA/-----Seitenumbr uch------ @ 0\ mod_1196175311226_0.doc @ 4165 @ @ 1
Summary of Contents for Swadro 2000
Page 261: ......