Frequency
◦
Specify center frequency for NDF1
◦
Type: Integer range [1000-1250000]
◦
Unit: kHz
•
Mode
◦
Select bandwith mode. Mode 7 is 25.6 MHz, 6 is 5.12 MHz, 5 is 2.56 MHz, 4 is
1.28 MHz.
◦
Options: 7, 6, 5, 4, 3, 2, 1, 0
•
Session
◦
Specify session ID to encode in the LT2P stream
◦
Type: Integer range [0-65535]
•
Dest. IP Address
◦
Stream destination IPv4 or IPv6 address. The address may be a multicast
IPv4 or IPv6 address.
◦
Type: String
•
Test Mode
◦
Enabling test mode will make NDX always start streaming regardless of the
network situation, likely to an unde
fi
ned MAC address. Only for testing!
◦
Type: On / O
ff
•
Gain
◦
Digital scaling of signal. Enter a smaller number here to attenuate the signal
digitally.
◦
Type: Integer range [0-65535]
•
Att
◦
Analog attenuation of signal. Entering larger numbers here will enable larger
analog attenuation of the signal.
◦
Type: Decimal range [0-31]
◦
Unit: dB
•
DC o
ff
set
◦
DC o
ff
set. This number will o
ff
set the signal digitally. Choose a value that
eliminates DC issues.
◦
Type: Integer range [0-4000]
www.kronback.com | [email protected]
NDX Manual - Setup pages