Type: Decimal
•
Servo adjust low-pass
◦
Set VCXO adjustment low-pass coe
ffi
cient. Default: 0.2. For example: 0.1 will
adjust VCXO by only 1/10 of the di
ff
erence towards the new VCXO value at
each servo update. 1.0 turns o
ff
low-pass
fi
lter
◦
Type: Decimal
•
Servo update interval
◦
The interval of the servo update loop in ms. Default: 500 ms
◦
Type: Integer
◦
Unit: ms
•
Reject di
ff
◦
Reject SYNC messages with an absolute time di
ff
erence more than this value.
Default: 1000000 ns
◦
Type: Integer
◦
Unit: ns
•
Reject max. count
◦
The maximum number of consecutive SYNC messages allowed to be rejected
before a new time o
ff
set is adopted. Enter 0 here to disable reject system.
Default: 8
◦
Type: Integer
MONITOR
On this page the MP output monitor function can be con
fi
gured.
REMOTE PHY1
On this page NDF and NDR can be con
fi
gured for the following streaming channels:
• NDF1 to SFP1
• SFP1 to NDR1
• SFP1 to NDR2
NDF1 to SFP1
•
Operation
◦
Disable, enable or start test tone(s) for NDF1. If Test tone or Test sweep is
selected internally generated tones will be streamed.
◦
Options: Disabled, Enabled, Test tone (200 KHz), Test sweep
www.kronback.com | [email protected]
NDX Manual - Setup pages
21 of 24