Ambient temp.
-25 to +50 °C (-13 to 122°F)
Protection
category
IP 65, acc. to IEC 529
(equivalent to NEMA 4x)
Full scale value
(Din= inner pipe diameter)
lower limit
(V
100% min
. = 0.5 m/s)
Q
100%min
[m
3
/h]
= ( Din [mm]/100 )
2
* 14.2
Q
100%min
[m
3
/h] = ( Din [inch] )
2
* 0.9
Q
100%min
[USGPM] = ( Din [inch])
2
* 3.9
upper limit
(V
100%max
= 17.1 m/s)
Q
100%max
[m3/h] = (Din [mm] )
2
* 0.05
Q
100%max
[m3/h] = (Din [inch] )
2
* 31.25
Q
100%max
[USGPM] = (Din [inch] )
2
* 138
Reynolds
number
Re > 10.000
Repeatability
0.2
R =
[%]
V
m
*D
i
R
=
repeatability in %
V
m
=
flow velocity [m/s]
D
i
=
inner pipe diameter [m]