If any discrepancies are detected the error message
PARAMERROR is displayed and a separate menu is activat-
ed in which the parameters concerned can be corrected (see
section D.6).
NOTE:
To save the programmed parameters in the Start Up menu
(fct. 1.0.0) press three times.
The signal converter is equipped with magnetic sensors (hall
contacts). This allows setting of the signal converter by
means of a hand-held bar magnet. Function of sensors with-
out removing the front cover is the same as the correspond-
ing keys.
Hold the bar magnet by the black rubber cap. Apply blue
end of the magnet (north pole) to the glass pane above the
magnetic sensors.