INSTALLATION
3
15
OPTITEMP TT 53 C/R
www.krohne.com
06/2018 - 4006523501 - MA OPTITEMP TT 53 R01 en
1
Hook one end of the clip into the rail.
2
Push the other end down until it snaps onto the rail.
3
Release by pushing the hook, and at the same time lift the clip out of the rail.
3.3 Rail-mount transmitter
These transmitters are intended for installation on a 35 mm rail according to EN 60715 /
DIN 50022.
1
Fix the upper part of the transmitter onto the rail.
2
Press the lower part of the transmitter against the rail.
3
To remove the transmitter, bend the locking device using a small screwdriver. Carefully pull
the transmitter in the forward direction.
Installation procedure: Step 2
Figure 3-3: Rail installation
CAUTION!
The manufacturer has developed the TT 53 R for an operating temperature range of
-40...+85
°
C / -40...+185
°
F.
To avoid destruction or damage of the device, always note the following items:
•
Assure that the operating temperature or the ambient temperature does not exceed the
permissible range.