![KROHNE OPTISONIC 1400 Quick Start Manual Download Page 34](http://html1.mh-extra.com/html/krohne/optisonic-1400/optisonic-1400_quick-start-manual_2004270034.webp)
3
ELECTRICAL CONNECTIONS
34
OPTISONIC 1400
www.krohne.com
10/2016 - 4005626301 - QS OPTISONIC 1400 R01 en
3.5.2 Description of the CG-number
The last 3 digits of the CG number (
5
,
6
and
7
) indicate the assignment of the terminal
connections.
Description of abbreviations and CG identifier for possible optional modules on terminals A and B
Figure 3-6: Marking (CG number) of the electronics module and input/output variants
1
ID number:5
2
ID number: 0 = standard
3
Power supply option
4
Display (language versions)
5
Input/output version (I/O)
6
1st optional module for connection terminal A
7
2nd optional module for connection terminal B
Abbreviation
Identifier for CG No.
Description
I
a
A
Active current output
I
p
B
Passive current output
P
a
/ S
a
C
Active pulse output, frequency output, status output or limit switch
(changeable)
P
p
/ S
p
E
Passive pulse output, frequency output, status output or limit switch
(changeable)
P
N
/ S
N
F
Passive pulse output, frequency output, status output or limit switch acc.
to NAMUR (changeable)
C
a
G
Active control input
C
p
K
Passive control input
C
N
H
Active control input to NAMUR
Signal converter monitors cable breaks and short circuits acc. to
EN 60947-5-6. Errors indicated on LC display. Error messages possible
via status output.
-
8
No additional module installed
-
0
No further module possible