Description of function -Troubleshooting
Control board
(p. 28-29)
The control board is equipped with two LEDs for trouble shooting.
L1: - permanently illuminated, if the overcurrent release has tripped.
- blinking, if the fuel flow valve detects only a low quantity of fuel in the tank or if
it is defctive.
L2: - illuminated, if the burner has been released but the flame is not burning. If the
flame starts burning within 2 seconds, the LED goes out.
If the LED does not go out the combustion has to be checked. If the LED is
not illuminated at all, the flame sensor has to be checked.
Nevertheless the cleaner can be used as a cold water high pressure cleaner
even if the burner is switched off.
The thermostat (4) is controlled via a thermo-sensor (18) mounted at the outlet of the
heaiting coil.
In the switchbox (below the operating panel), a fuse (F1) is installed on the board
protecting the motor (11) of the fuel pump and the ventilator. If the motor is overloaded
the fuse trips. This may happen if the fuse pump is blocked or sluggish - the same
applies if the ventilator is blocked or sluggish or in case of an electrical malfunction.
Another fuse (F2) on the board trips, if the ignition transformer (17) is faulty.
To avoid an overheating of the burning chamber a flow indicator (10) is installed in the
high pressure system between the high pressure pump (6) and the burning chamber
enabling a fuel supply only if water streams through the heating coil at the same time.
Summary of Contents for 11/130
Page 30: ...30 Complete Assembly...
Page 32: ...32 Electronics switchbox...
Page 36: ...36 Combustion chamber...
Page 38: ...38 Combustion chamber...
Page 44: ...44 Valve housing...
Page 48: ...48 Hose drum Special accessory Upgrade kit 44 152 2...
Page 56: ...Reprint only allowed with the authorization of As date of 15 04 2009 Order No 30 702 1 R...