Cold water mode
1. Connect to water supply and determine whether the water tank fills up
completely and the float valve stops.
2. Ignition (2) to OFF.
3. Main switch (1) to ON.
4. Open high pressure gun. The apliance started, the pump sucks water from the
water tank and moves the water through the heating coil to the lance, the
pressure is increased.
ATTENTION!!
If the pressure is not built up immediately, there is still air
in the pump. Open and close the gun repeatedly to press
the air from the machine.
Description of function -Troubleshooting
Hot water mode
St
art the machine just like in cold water mode and then turn the rocker switch (2) for
the burner to ON. Then, turn the rotary switch on the thermostat, (4) located on the
front, to the desired temperature (at least 40 °C) in order to activate the burner, i.e.,
that fuel is injected.
The manometer (14) on the fuel pump shows approx. 10 bars. If this reading is not
displayed, check whether
1. there is heating oil in the tank
2.
the motor fuse ( 11) in the switch box (below the operation panel) has tripped.
3. the fuel sieve (15) or the fuel sieve in the pump (13) is dirty.
4. the fuel pump does no operate smoothly or is blocked.
5. the ventilator jams.
The thermostat grants permission to open the solenoid valve. The burner starts
and
heats up the water to the set temperature. The burner switches off as soon as the
desired temperature has been reached.
If the temperature drops again, the burner switches on automatically thus guaranteeing
the required constant temperature.
22
Summary of Contents for 11/130
Page 30: ...30 Complete Assembly...
Page 32: ...32 Electronics switchbox...
Page 36: ...36 Combustion chamber...
Page 38: ...38 Combustion chamber...
Page 44: ...44 Valve housing...
Page 48: ...48 Hose drum Special accessory Upgrade kit 44 152 2...
Page 56: ...Reprint only allowed with the authorization of As date of 15 04 2009 Order No 30 702 1 R...