Decommissioning
16
Decommissioning
- Switch off the master switch (position "0").
- Pull the plug out of the power socket.
- Turn off the water supply.
- Open the gun until the pressure is gone.
- Lock the gun.
- Disconnect the water hose.
- Slacken the connections of the high pressure hose and gun and unscrew the high
pressure hose from the machine (appliances without hose drum).
Anti-Freeze Protection
The machine is normally still partially filled with water after work has been completed.
It is therefore necessary to take special precautions to protect the machine from frost.
- Completely empty the machine of water
Disconnect the machine from the water supply and switch off the ignition.
Switch on the master switch and open the gun. The pump now presses the
remaining water out of the heating coil. Do not allow the machine to run for
longer than a minute without water.
- Fill the machine with anti-freeze
If the machine is not in use for lengthy periods of time, it is advisable to
pump anti-freeze into the machine, especially in winter. For this purpose, fill the
antifreeze agent into the water box and turn on the machine without ignition
(rocker switch (16) to „0“). Wait with opened gun, until the agent comes out of
the nozzle.
However, the best protection against frost is to keep
the machine in a place that is safe from frost.
Summary of Contents for 11/130
Page 30: ...30 Complete Assembly...
Page 32: ...32 Electronics switchbox...
Page 36: ...36 Combustion chamber...
Page 38: ...38 Combustion chamber...
Page 44: ...44 Valve housing...
Page 48: ...48 Hose drum Special accessory Upgrade kit 44 152 2...
Page 56: ...Reprint only allowed with the authorization of As date of 15 04 2009 Order No 30 702 1 R...