VSM-4x4HFS - The VSM-4x4HFS RS-232 Communication Protocol
77
77
Command
–
SCLR-AS
Command Type
– Multiviewer/Scaler
Command Name
Permission
Transparency
Set:
SCLR-AS
End User
Public
Get:
SCLR-AS?
End User
Public
Description
Syntax
Set:
Set auto-sync features (auto sync-off)
#
SCLR-AS
␠
P1,P2
␍
Get :
Get auto-sync features (auto sync-off)
#
SCLR-AS?
␠
P1
␍
Response
Set / Get : ~
nn
@
SCLR-AS
␠
P1,P2
␠
OK
␍␊
Parameters
P1
–1=OUT A, 2=OUT B, 3=OUT C, 4=OUT D *=ALL
Note that all 4 scalers have the same auto sync-off status
P2
– On/Off – 0=Off; 1=On
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the auto sync features for the selected scaler
Command
–
SHOW-OSD
Command Type
– Multiviewer/Scaler
Command Name
Permission
Transparency
Set:
SHOW-OSD
End User
Public
Get:
SHOW-OSD?
End User
Public
Description
Syntax
Set:
Set the OSD display (INFO menu item in OSD)
#
SHOW-OSD
␠
P1
␍
Get :
Get the OSD display (INFO menu item in OSD)
#
SHOW-OSD?
␠
␍
Response
Set / Get : ~
nn
@
SHOW-OSD
␠
P1,P2
␠
OK
␍␊
Parameters
P1
–1=OUT A, 2=OUT B, 3=OUT C, 4=OUT D *=ALL
Note that all 4 scalers have the same OSD display
P2
– On/Off – 0=Off; 1=On
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Displays the OSD of the selected Scaler