VSM-4x4HFS - The VSM-4x4HFS RS-232 Communication Protocol
71
71
Command -
PRST-VID?
Command Type - System
Command Name
Permission
Transparency
Set:
-
-
-
Get:
PRST-VID?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get video connections from saved preset
#
PRST-VID?
␠
preset, out
␍
#
PRST-VID?
␠
preset, *
␍
Response
~nn@
PRST-VID
␠
preset, in>out
␍␊
~nn@
PRST-VID
␠
preset, in>1, in>2, in>3
, …
␍␊
Parameters
preset
–
1,2,3 or 4
in
– 1=IN1; 2=IN2; 3=IN3; 4=IN4; 5=OFF
>
- connection character between in and out parameters
out
–
1=OUT A; 2=OUT B; 3=OUT C; 4=OUT D;
'*' for all outputs
Notes
In most units, video and audio presets with the same number are stored and recalled together by
commands #PRST-STO and #PRST-RCL
Examples
Store current audio and video connections,
volumes and modes to preset 4
#PRST-STO 4
␍
~PRST-STO 4
␍␊
Recall audio and video connections from
preset 3
# PRST-RCL 3
␍
~PRST-RCL 3
␍␊
Show source of video output 2 from preset 3
#PRST-VID? 3,2
␍
~PRST-VID 3, 4>2
␍␊
Command
–
SIGNAL
Command Type - System
Command Name
Permission
Transparency
Set :
-
-
-
Get
SIGNAL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get input signal lock status
#
SIGNAL?
␠
P1
␍
Response
~
nn
@
SIGNAL
␠
inp_id, status
␍␊
Parameters
Inp_id (Input number)
– 1=IN1; 2=IN2; 3=IN3; 4=IN4; *=ALL
status
– 0=signal is not valid; 1=signal is valid
Response triggers
After execution, response is sent to the com port from which the
Get
was received
Response is sent after every change in input signal status
ON to OFF
, or
OFF to ON