VS-6464DN - Using the Configuration Menu
27
The display reverts to the output/input display showing that the selected
output is turned off with the input being blank.
7.1.3
Setup Menu
—7: EDID, Assignment to an Input
This option assigns an EDID to between one and eight inputs at a time which are
stored in non-volatile memory. More than eight EDID assignments must be
assigned in separate batches of eight.
Each input on the
VS-6464DN
has a factory default EDID loaded (see
Section
15
).
The EDID for each input can be changed independently via the menu (described
below) or by uploading an EDID binary file to each input via the RS-232 port using
Kramer EDID Designer software (available for download from
http://www.kramerelectronics.com)
.
Note
: It is necessary to have a display/device connected to the output from which
you want to read the EDID. Failure to do so results in the default EDID being
written to storage.
To assign an EDID to between one and eight inputs:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
Figure 2
).
The following is displayed:
SETUP EDID
ENTER to View EDID and Set EDID
3. Press ENT.
The current EDID matrix configuration is displayed.
4. Using the numeric keys, enter the input in which to store the EDID (in this
example, 08), and enter the output (in this example, 05) from which to read
the EDID.
The following is displayed:
00 01 02 03 04 05 06 07 08
05 out05 => in08