32
VS-6464DN - Using the Configuration Menu
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU.
The following is displayed:
IN: 01 02 03 04 05 06 07 08 09 10 11
SIG: Y X Y Y Y Y X Y Y Y X
Y indicates that a signal is detected and X indicates that no signal is
detected on the relevant input.
3. Do one of the following:
Press BREAKAWAY to exit the Config Menu
Wait approximately 15 seconds for the operation to time out
Press MENU to move to the next Config Menu option
7.2.2
Config Menu
—Output Load Detection Display
This option displays a list of outputs and indicates which have loads attached to
them.
To display a list of outputs and attached loads:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
OUT: 01 02 03 04 05 06 07 08 09 10 11
LOAD: Y X Y Y Y Y X Y Y Y X
Y indicates that a load is attached and X indicates that no load is
detected on the relevant output.
3. Do one of the following:
Press BREAKAWAY to exit the Config Menu