Kramer Electronics Ltd.
UHD Matrix Switcher
– Protocol 3000
62
BUILD-DATE
Functions
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device build date
#
BUILD-DATE?
CR
Response
~nn@
BUILD-DATE
SP
date
SP
time
CR LF
Parameters
date
–
Format:
YYYY/MM/DD
where
YYYY
= Year,
MM
= Month,
DD
= Day
time
–
Format:
hh:mm:ss
where
hh
= hours,
mm
= minutes,
ss
= seconds
K-Config Example
“#BUILD
-
DATE?”,0x0D
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory default configuration
#
FACTORY
CR
Get:
-
-
Response
~nn@
FACTORY
SP
OK
CR LF
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
“#FACTORY”,0x0D
HELP
Functions
Permission
Transparency
Set:
-
-
-
Get:
HELP
End User
Public
Description
Syntax
Set:
-
-
Get:
Get command list or help for specific command
#
HELP
CR
Response
Multi-line:
~nn@Device available protocol 3000 commands:CR LF
command,
SP
command...
CR LF
Parameters
COMMAND_NAME
– name of a specific command
Notes
To get help for a specific command use:
HELP
SPCOMMAND_NAMECR LF
K-Config Example
“#HELP”,0x0D