Kramer Electronics Ltd.
VS-3232DN-EM
– Protocol 3000
119
AUD-LVL
Functions
Permission
Transparency
Set
AUD-LVL
End User
Public
Get
AUD-LVL?
End User
Public
Description
Syntax
Set
Set audio level in specific amplifier stage
#
AUD-LVL
SPstage,channel,volumeCR
Get
Get audio level in specific amplifier stage
#
AUD-LVL?
SPstage,channelCR
Response
~nn@
AUD-LVL
SPstage,channel,volumeCR LF
Parameters
stage
–
1/IN
(input),
2/OUT
(output)
channel
– input or output number:
1-32
(varies according to installed input / output cards, see
volume
– audio level in Kramer units:
0-70
,
++
(increase current value),
--
(decrease current value)
Response Trigger
Notes
The
VOLUME
command can also be used to set simple output audio volume.
A minus sign precedes negative values.
K-Config Example
Set the audio level of output 8 to 30:
“#AUD
-LVL
2,8,30”,0x0D
Increase the audio level of input 3 by 1 unit:
“#AUD
-
LVL 1,3,++”,0x0D
BALANCE
Functions
Permission
Transparency
Set
BALANCE
End User
Public
Get
BALANCE?
End User
Public
Description
Syntax
Set
Set the balance level
#
BALANCE
SPout_channel,balance_levelCR
Get
Get the current balance level
#
BALANCE?
SPout_channelCR
Response
~nn@
BALANCE
SPout_channel,balance_levelCR LF
Parameters
out_channel
– output number:
1-32
(varies according to installed output cards, see
balance_level
– balance level in Kramer units:
0-100
,
++
(increase current value),
--
(decrease
current value)
Response Trigger
Notes
A minus sign precedes negative values
K-Config Example
Set the balance level of output 5 to 50:
“#BALANCE 5,50”,0x0D
Increase the balance level of output 5 by 1 unit:
“#BALANCE 5,++”,0x0D