VP-771 - Controlling the VP-771
49
49
8.3.3.2 Connecting the ETHERNET Port via a Network Hub (Straight-
Through Cable)
You can connect the Ethernet port of the
VP-771
to the Ethernet port on a network
hub or network router, via a straight-through cable with RJ-45 connectors.
8.3.3.3 Ethernet Port Configuration and Control
Use the Kramer K-UPLOAD software to configure and control the
VP-771
via the
Ethernet.
The latest version of K-UPLOAD and installation instructions can be
downloaded from the Kramer Web site at
www.kramerelectronics.com
8.4
Controlling the VP-771 via the REMOTE Terminal Block
Connector
The REMOTE terminal block connectors include:
•
A PIP pin and a G pin which are used for toggling between the Single and
Dual window modes, and for selecting a PiP input
•
Nine input pins (defined in the table below) and a G pin for selecting an input
PIN#
Input Source
PIN#
Input Source
PIN#
Input Source
1
HDMI 1
4
PC 2
7
CV 2
2
HDMI 2
5
COMP.
8
DP
3
PC 1
6
CV 1
9
SDI
The contact closure remote control pins operate in a similar way to the INPUT
buttons (see
Section 8.1
). Using the contact closure remote control (also known as
push-to-make momentary contact) you can select any of the inputs. To do so,
momentarily connect the required input pin (1 to 9) on the REMOTE terminal block
connector to the G (Ground) pin of the REMOTE terminal block connector, as
Figure 29
illustrates.
Do not
connect more than one input PIN to the GND PIN at the same
time.