VP-553 - The VP-553 RS-232 Communication Protocol
73
73
Command
–
Equalization Level
Command Type
– [Audio]
Command Name
Permission
Transparency
Set:
EQ-LVL
End User
Public
Get:
EQ-LVL?
End User
Public
Description
Syntax
Set:
Set the equalization level
#
EQ-LVL
␠
P1,P2,P3
␍
Get :
Get the equalization level
#
EQ-LVL?
␠
P1,P2
␍
Response
Set / Get : ~
nn
@
EQ-LVL
␠
P1,P2,P3
␍␊
Parameters
P1 (Audio output number)
– 0=Audio out; 1=Scaler 1; 2=Scaler2
P2 (frequency number)
– 0=120; 1=200; 3=500; 4=1200; 5=3000; 6=7500; 8=12000
P3 (Level)
– 0=-10dB 20=0dB; 40=10dB
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the EQ level for the selected frequency of the selected audio output
Command
–
Show the OSD
Command Type
– [Video]
Command Name
Permission
Transparency
Set:
SHOW-OSD
End User
Public
Get:
SHOW-OSD?
End User
Public
Description
Syntax
Set:
Set the OSD display
#
SHOW-OSD
␠
P1
␍
Get :
Get the OSD display
#
SHOW-OSD?
␠
␍
Response
Set / Get : ~
nn
@
SHOW-OSD
␠
P1
␍␊
Parameters
P1 (Scaler number)
– 0=Both Off; 1=1 On; 2=2 On; 99=Both On
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Displays the OSD of the selected Scaler