72
VP-553 - The VP-553 RS-232 Communication Protocol
Command
–
PC Auto Sync
Command Type
– [Video]
Command Name
Permission
Transparency
Set:
SCLR-PCAUTO
End User
Public
Get:
End User
Public
Description
Syntax
Set:
Set
#
SCLR-PCAUTO
␠
P1,P2
␍
Get :
Response
Set / Get : ~
nn
@
SCLR-PCAUTO
␠
P1,P2….
␍␊
Parameters
P1 (Scaler number)
–1=Scaler 1; 2=Scaler2
P2 (Off/On)
– 0=Off; 1=On
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the PC Auto sync of the selected scaler
Command
–
Scaler Audio Delay
Command Type
– [Audio]
Command Name
Permission
Transparency
Set:
SCLR-AUDIO-DELAY
End User
Public
Get:
SCLR-AUDIO-DELAY?
End User
Public
Description
Syntax
Set:
Set the scaler audio delay
#
SCLR-AUDIO-DELAY
␠
P1,P2
␍
Get :
Get the scaler audio delay
#
SCLR-AUDIO-DELAY?
␠
P1
␍
Response
Set / Get : ~
nn
@
SCLR-AUDIO-DELAY
␠
P1,P2
␍␊
Parameters
P1 (Audio output number)
– 0=Audio out; 1=Scaler 1; 2=Scaler2
P2 (Level selecetion)
– 0=Off; 1 to8=10ms to80ms in 10ms steps; 9=Auto
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the audio delay for the selected audio output