48
VP-553 - Using the Embedded Web Pages
Figure 44: The Data Routing Page
Click the Set changes button to set the changes.
RS-232 Data Port: for each HDBaseT port you can set the following data settings:
Baud Rate
: 4800, 9600, 19200, 38400, 57600 or 115200
Data Bits
: 5, 6, 7 or 8
Parity
: NONE, EVEN, ODD, MARK or SPACE
Stop Bits
: 1 or 2
Flow Control
: OFF or ON
This way you can set the serial data in line with the serial data passed through.
SID-X2N Data transfer: if the Kramer SID-X2N is connected to an HDBT port
7.9
The Authentication Page
The Authentication page lets you set the user name and password as well as
setting the inactivity logout.
Figure 45
shows the Authentication page: