VP-553 - The VP-553 RS-232 Communication Protocol
71
71
Command
–
Scaler As?
Command Type
– [Audio]
Command Name
Permission
Transparency
Set:
SCLR-AS
End User
Public
Get:
SCLR-AS?
End User
Public
Description
Syntax
Set:
Set the
#
SCLR-AS
␠
P1,P2
␍
Get :
Get the
#
SCLR-AS?
␠
P1
␍
Response
Set / Get : ~
nn
@
SCLR-AS
␠
P1,P2….
␍␊
Parameters
P1
–(Scaler Number)1=Scaler 1; 2=Scaler2
P2 (Off/On)
– 0=Off; 1=On
Response triggers
Response is sent to the com port from which the
Set
(before execution)
/ Get
command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
Sets the Auto Sync features for the selected Scaler
Command
–
Image Proportions
Command Type
– [Video]
Command Name
Permission
Transparency
Set:
IMAGE-PROP
End User
Public
Get:
IMAGE-PROP?
End User
Public
Description
Syntax
Set:
Set the image size
#
IMAGE-PROP
␠
P1
␍
Get :
Get the image size
#
IMAGE-PROP?
␠
P1,…,P6
␍
Response
Set / Get : ~
nn
@
IMAGE-PROP
␠
P1,P2….
␍␊
Parameters
P1 (Scaler number)
–1=Scaler 1; 2=Scaler2
P2 (Status)
– 0=Over Scan; 1=Full; 2=Best Fit; 3=PanScan; 3=Letter Box; 5=Under 2; 6=Under 1
Response triggers
Response is sent to the com port from which the
Set
(before execution)
/ Get
command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the image properties of the selected scaler