Multicheck6010
EN
- 66 -
4.2.2 Continuity test
How to perform low current continuity measurement
Step 1
Select the Continuity function with the FCT key and select the Cont mode with the
▲▼
and
◀▶
navigation keys. The following menu will be displayed:
Figure 4 8: Continuity measurement menu
Step 2
Set the following limit value:
•
Límit:
limit resistance value using the
▲▼
and
◀▶
navigation keys.
Step 3
Connect test cable to the instrument and the item under test. Follow the connection
diagram shown in figure 4.9 to perform the
Continuity
measurement.
Figure 4 9: Connection of universal test cable
Step 4
Check the warnings and online voltage/terminal monitor on the display before starting
the measurement. If everything is OK and the is shown, press the TEST key to
start the measurement. The actual measuring result with
or indication (if
applicable) will be displayed during the measurement.
As this is a continuous test, the function will require stopping. To stop the measurement
at any time press the TEST key again. The last measured result will be displayed
together with the
or
indication (if applicable).