Refer to vent systems manufacturer's installation manual for complete installation instructions.
Installation must conform with venting requirements and restrictions as outlined in this manual.
Simpson Dura-Vent DV-GS 5” x 8” direct vent system (horizontal and vertical terminations).
Ameri-Vent Direct Chimney System 5” x 8” (horizontal and vertical terminations).
Selkirk Metalbestos Chimney System 5” x 8” (horizontal and vertical terminations).
Metal Fab Chimney System: 5” x 8” (horizontal and vertical terminations).
ICC Chimney System: 5” x 8” (horizontal and vertical terminations).
RLH Chimney System: 5” x 8” (horizontal and vertical terminations).
Security Chimney System: 5” x 8” (horizontal and vertical terminations).
This fireplace is designed to be used with rigid pipe only.
IMPORTANT: Consult local and national installation codes to assure adequate combustion and ventilation air is available.
HORIZONTAL VENT SYSTEM CLEARANCES
TOP
BOTTOM
SIDES
3 inches (76 mm) at wall pass thru
1 inch (25 mm)
1 inch (25 mm)
HORIZONTAL TERMINATIONS
MINIMUM: 90
˚
elbow + termination cap.
MAXIMUM: 90
˚
elbow + 20 ft. (6.096 m) hori termination cap.
VENTING
PAGE 14
APPROVED VENTING
MINIMUM VERTICAL RISE: 3 ft. (914 mm) ve termination cap.
MAXIMUM VERTICAL RISE: 36 ft. (10.97 m) ve termination cap.
VERTICAL TERMINATIONS
HORIZONTAL & VERTICAL COMBINATION TERMINATIONS
20 ft. (6.10 m) horizontal / 20 ft. (6.10 m) vertical.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
VERTICAL VENT SYSTEM CLEARANCES
TOP
BOTTOM
SIDES
1 inch (25 mm)
1 inch (25 mm)
1 inch (25 mm)
IMPORTANT: Flame height and appearance will vary depending upon venting configuration and type of fuel used.
NOTE: Page 14 has information on restrictor installation in conjunction with venting installation. Page 36 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED WHEN USING A 90-DEGREE ELBOW TO
HORIZONTALLY POSITION VENT SYSTEM.
IMPORTANT: KOZY HEAT WALL PASS-THRU, PART #800-WPT (4-1/2” (114 mm) - 6-1/2” (165 mm) ) WALL THICKNESS OR
#800-WPT2 (6-1/2” (165 mm) - 12-1/2” (318 mm) ), MUST BE USED ON ALL HORIZONTAL VENT RUNS.