Fault search
Fault
Cause
Remedy
Light does not
switch
Defective bulb
Replace the bulb
Back-up turned off
Turn on
Brightness response set to dark
Turn setting screw continuously toward bright
Power supply interrupted
Check cable, repair if necessary
Detection time not correctly adjusted
Correct area - walk test in the detection area
Lens is dirty
Clean the lens (damp cloth)
Do not use solvents
Light on
continuously
Constant movement in the detection area
(animals, trees, etc.)
Remove the heat source
Readjust the motion switch if necessary
ON time is set too long
Reduce time using the setting screw
Independent,
unwanted
Switching
Switching on after a power failure
Normal case - Warm-up phase approx. 90 sec.
Sunlight on the lens
Change brightness setting
Trees, shrubs, etc. in the wind activate
switching
Adjust detection area or partially cover lens with the
enclosed plastic covers
Detection of road transport
Decrease range (e.g. by setting the set screw to
„Meter“) or partially cover lens with the enclosed plastic
covers
Switching inductive loads
(protection, relays, etc.)
Switch noise filter in parallel to the consumer