Installation
AM4011
Page 3 - 6
ID 1022-1626, Rev. 1.0
P R E L I M I N A R Y
In the case of a running system, the following occurs:
•
The BLUE HS LED displays long blinks.
When the carrier IPMI controller detects the module, it sends a command to the mod-
ule to perform long blinks of the BLUE HS LED.
•
The BLUE HS LED turns off.
The Intelligent Platform Management Controller on the carrier reads the Module Cur-
rent Requirements record and the AMC Point-to-Point Connectivity record.
If the module FRU information is valid and the carrier can provide the necessary pay-
load power, the BLUE HS LED will be turned off.
The carrier now enables the payload power for the module.
8. The AMC module is now ready for operation.
For operation of the AM4011, refer to appropriate AM4011-specific software, application,
and system documentation.
Note ...
If the module FRU information is invalid or the carrier cannot provide
the necessary payload power, the BLUE HS LED stops blinking and
remains lit. Should this problem occur, please contact Kontron’s Tech-
nical Support.