Technical data:
KDC 4000
KDC 8000
Max. capacity pre-cleaning - tonnes/hour
40
80
App. capacity seed cleaning - tonnes/hour
8
13
App. capacity malting barley - tonnes/hour
5
8
Screen drum motor size - kW (HP)
1,5 (2,0)
2,2 (3,0)
Screen drum motor rpm
21,9
23
Blower for aspirator motor size - kW (HP)
4,0 (5,5)
4,0 (5,5)
Blower for aspirator motor rpm
3.000
3.000
Auger drive motor size - kW (HP)
0,75 (1,0)
1,1 (1,5)
Auger drive rpm
450
240
Control panel power supply
3x400V / 50 Hz
Rated 13,4A
3x400V / 50 Hz
Rated 15A
Inlet for crop
OK200
FK250
Outlet for cleaned crop
OK200
FK250
Conveying pipes for impurities
OK200
OK200
Outlet from auger
OK160
OK200
Inner screen area - m
2
4,1
7,5
Outer screen area - m
2
6,5
10
Weight of cleaner without screens - kg
890
1.425
Above capacities applies for wheat 700 kg/m
3
.