922-20297001/1.2
167
•
Weight
: 17.0 kg (air), 10.8 kg (water)
•
Materials
: Titanium, Elastomeric Polyurethane
•
Connector type
: SEACON
®
•
Connector model
: MINK-10-FCRL (Telemetry and Power)
Power requirements
These power characteristics summarize the supply power requirements for the M3 Sonar
FLS system.
Sonar Processor
•
Power adapter input voltage
: 120/240 VAC
•
Laptop input voltage
: 19.5 VDC @ 180W (max)
Sonar Head
•
Input voltage
: 12 to 36 VDC
•
Input power
: 44W (avg.), peak power < 70W, mode dependant
Environmental requirements
These specifications summarize the temperature requirements and other environmental
standards for the M3 Sonar FLS system.
Sonar Processor
The Sonar Processor uses a high-quality commercial-off-the-shelf laptop computer
workstation. This computer is intended to be installed inside in an area suitable for extended
human habitation. Contact your Kongsberg Mesotech representative for information about
the current model that is delivered with your M3 Sonar FLS system.
Sonar Head
Operating temperature
: -2° to + 38 °C
Storage temperature
: -40 to +55 °C
The stated operation temperature range is for the Sonar Head in water. The Sonar Head can
be powered on and started at temperatures between -20° to +45° C. There is a built-in