After the installation is completed in dock, a full set of alignment measurements must
be carried out. This job has to be done by professional and experienced land surveyors,
typically equipment is electronic total stations. Kongsberg Maritime can not be expected
to have qualified personnel for such work.
The results, with all measurements taken in a common vessel coordinate system, are to
be entered in the EM 122 Operator Station.
NB! Some external sensors may have been set up to output data referred to a location
that differ from where it is physically mounted. It is the x, y, z values for this location
that must be entered into the EM 122 Operator station.
Note
The given accuracies in the tables in this chapter, are maximum values, and if easily
achievable, better accuracies should be obtained. The relative heading accuracy
between Rx and Tx must be within ±0.1º.
All distance measurements are to done to an accuracy of 5 cm both horizontally and
vertically.
The procedures and requirements made by the manufacturers of the external sensors
connected to the EM 122 must also be taken into account.
Vessel coordinate system
A Cartesian coordinate system must be defined for the vessel. The following definition
must be adhered to:
• X = forwards
• Y = to starboard
• Z = pointing downwards
There is no restriction on where the coordinate system’s origo is located.
Note
The sea surface with the vessel in normal trim defines the horizontal (X-Y) plane. The
water line should therefore be marked on the hull with the vessel in normal trim before
dry docking for installation of transducers.
317669/B
97
Summary of Contents for EM 122
Page 1: ...EM 122 Multibeam echo sounder Installation Manual...
Page 2: ......
Page 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Page 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Page 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Page 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Page 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Page 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Page 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Page 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Page 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Page 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Page 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Page 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Page 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Page 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Page 154: ...2013 Kongsberg Maritime...