Cable layout and interconnections
C7 - Ship’s Ethernet
The Operator Station is equipped with two Ethernet ports interface boards, one is used
to communicate with the ship’s Ethernet while the other (C17) is used to communicate
with the Transceiver Unit.
The Ethernet cables must be provided by the installation shipyard. For cable details,
see
on page 141
C8 / C9 - AC power
These are AC mains cables.
All AC mains cables are normally supplied by the manufacturer.
C14 - Serial A
This serial line is intended for a sound speed probe. If a sound speed probe is not used,
the serial line may be used for other purposes.
See
on page 134
The cables must be provided by the installation shipyard.
C15 - Serial B
This serial line is intended for a tide/depth sensor. If such a sensor is not used, the serial
line may be used for other purposes.
See
on page 134.
The cable must be provided by the installation shipyard.
C17 - Transceiver Unit RJ-45 interface
The Operator Station has two Ethernet outlets. One is used to communicate with the
ship’s Ethernet (C7) while the other C17 is used to communicate with the Transceiver
Unit.
See
on page 141.
The cable must be provided by the installation shipyard.
C19 - Synchronisation system
Refer to the Transceiver Unit cabling.
C24 - Remote
Refer to the Transceiver Unit cabling.
317669/B
67
Summary of Contents for EM 122
Page 1: ...EM 122 Multibeam echo sounder Installation Manual...
Page 2: ......
Page 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Page 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Page 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Page 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Page 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Page 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Page 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Page 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Page 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Page 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Page 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Page 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Page 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Page 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Page 154: ...2013 Kongsberg Maritime...