EM 122
and designed to ensure a good ground connection. The glands used must be firmly
attached to, and in good electrical contact with, a metal structure grounded in accordance
with these recommendations.
Electrical continuity must be ensured along the entire length of all cable coverings,
particularly at joints and splices. In no case should the shielding of cables be used as the
only means of grounding cables or units.
Cable connections
All cable connections are shown on the applicable cable plan and interconnection
diagrams.
Where the cable plan shows cable connections outside an equipment box outline, the
connections are to be made to a plug or socket which matches the plug or socket on
that particular item of equipment.
Where two cables are connected in series via a junction box or terminal block, the
screens of both cables must be connected together but not grounded.
Cable terminations
Care must be taken to ensure that the correct terminations are used for all cable
conductors. All cable work has to be done according to IPC 620 standard or similar
standards.
Cable identification
Cable identification codes corresponding to the cable number shown in the cable plan
must be attached to each of the external cables. These identification codes should be
positioned on the cable in such a way that they are readily visible after all panels have
been fitted. In addition, each cable conductor should be marked with the terminal board
number or socket to which it is connected.
150
317669/B
Summary of Contents for EM 122
Page 1: ...EM 122 Multibeam echo sounder Installation Manual...
Page 2: ......
Page 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Page 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Page 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Page 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Page 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Page 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Page 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Page 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Page 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Page 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Page 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Page 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Page 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Page 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Page 154: ...2013 Kongsberg Maritime...