MAINTENANCE
Service procedure
Every 250 hours service
4-45
Clean element in air conditioner recirculation filter
0.
1. Loosen knob (1), remove filter inspection cover (2), then
open filter inspection cover (3).
2. Pull out filters (4) and (5) in the direction of the arrow.
3. Clean with compressed air in the same way as for the fresh
air filter.
If the filter is extremely dirty, rinse it in water.
After rinsing the filter, dry it completely before installing it
again.