OPERATION
Explanation of components
Fuse
3-45
Fuse
0.
NOTICE
Before replacing a fuse, be sure to turn off the starting switch.
The fuses protect the electrical equipment and wiring from
burning out.
If the fuse becomes corroded, or white powder can be seen, or
the fuse is loose in the fuse holder, replace the fuse.
Replace the fuse with another of the same capacity.
Remove cover (1). The fuse boxes are A and B.
Fuse capacity and name of circuit
0.
Fuse box A
0.
AE42081B-A
Front of machine
No.
Name of circuit
(1)
20A
Starting switch
(2)
10A
Hazard warning flashing lamp
(3)
10A
HST control A
(4)
10A
Parking brake A
(5)
10A
Instrument panel
(6)
10A
Radio A, Room lamp
(7)
10A
Auxiliary pwe
(B24V)
(8)
10A
Head Lamp L.H.
(9)
10A
Head Lamp R.H.
(10)
10A
Turn signal lamp
(11)
10A
Back lamp, Stop lamp
(12)
20A
HST control B
(13)
10A
Work equipment positioner
(14)
10A
Wiper
(15)
10A
Radio B
Summary of Contents for WA250PT-5H
Page 2: ......
Page 3: ...FOREWORD 11...
Page 16: ...Contents FOREWORD 1 14...
Page 24: ...SAFETY 2 2...
Page 58: ...Precautions with tires SAFETY Precautions when storing tires 2 36...
Page 60: ...OPERATION 3 2...
Page 233: ...TECHNICAL DATA 45...
Page 235: ...TECHNICAL DATA Technical data 5 3...
Page 250: ...Central lubrication system ATTACHMENTS OPTIONS 6 14...
Page 251: ...INDEX 67...
Page 252: ...INDEX 7 2...
Page 255: ...Index 7 5...