Trouble
Fault hours are added in the fault hour meter and can not be
deleted.
All fault messages are displayed on LED (A) as a collective
fault.
All fault messages can be acknowledged and deleted with but-
tons (B).
The display mode will start with one of two buttons (C).
When grease has leaked from pressurized safety valve (1),
consult your Komatsu distributor.
The pump has an automatic level control. If the grease level
falls below “min” mark, the lubrication process is stopped with
the fault message “FLL” shown on the display.
If fault message “FLL” is displayed, fill up with grease and reset
the fault with button (B).
Fault message
Display
Denotation
Explanation
Control function
Fault Low Level
The minimum level in the grease
tank has been reached.
The control unit is in the FAULT
mode. The sequence of opera-
tions is stopped.
Fault Cycle Switch
No signal from cycle switch during
pump running time.
The control unit is in the FAULT
mode. The sequence of opera-
tions is stopped.
If the fault message will appear again after the reset, consult your Komatsu distributor.
INITIAL 10 HOURS MAINTENANCE (ONLY FOR THE FIRST 100 HOURS)
For the first 100 hours of operation on a new machine, press
the switch shown in the figure every 10 hours to actuate the
manual greasing.
AUTO-GREASING
ATTACHMENTS AND OPTIONS
6-22
Summary of Contents for H75051
Page 2: ... ...
Page 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 66: ......
Page 74: ...Outside of cab 1 Slow blow fuse 2 Frame lock bar GENERAL VIEW OPERATION 3 8 ...
Page 310: ......
Page 396: ......
Page 397: ...SPECIFICATIONS 5 1 ...
Page 400: ......
Page 424: ......
Page 425: ...REPLACEMENT PARTS 7 1 ...